Triple Rated rotary phase converters

home.gif (396 bytes)

 
PhaseMAXX
(T) Series Triple Rated 

 HP Ratio Largest / Total - (1:3)

 

HP Frame Model Largest HP Total HP Resistive Load KVA
7.5 213T PhaseMAXX - 3T 3 9 3.9
10 215T PhaseMAXX - 5T 5 15 6.5
15 254T PhaseMAXX - 7T 7.5 22 9.75
20 256T PhaseMAXX - 10T 10 30 13.0
25 284T PhaseMAXX - 13T 13 39 16.9
30 286T PhaseMAXX - 15T 15 45 19.5
40 324T PhaseMAXX - 20T 20 60 26.0
50 326T PhaseMAXX - 25T 25 75 32.5
60 364T PhaseMAXX - 30T 30 90 39.0
80 365T (+) PhaseMAXX - 40T 40 120 52.0
100 404T PhaseMAXX - 50T 50 150 65.0
120 405T (-) PhaseMAXX - 60T 60 180 78.0
150 444T PhaseMAXX - 75T 75 225 97.5

PhaseMAXX (T) Series (Triple Rated) Rotary Phase Converters are supplied with built in magnetic starter, overload protection, and Hand/Off/Auto or Stop/Start controls. These converters can operate single or multiple motors, as well as resistive loads. The KVA capability for resistive loads is 1.3 times the (Largest HP) rating. Triple Rated rotary phase converters are ideally suited for grain handling, woodworking equipment, hoists, printing machines, irrigation pivots, air conditioners, and machine tools. Motors connected to Triple Rated rotary phase converters will develop full rated HP.  

The above table is presented as a  "Class 1"   general guide only. Converter "Class" refers to the size of converter versus load.  

When price-comparing converters between different manufacturers, especially compare the HP and Frame size of the converter.
 
Consult PhaseMAXX to properly size a converter for your specific application.

home.gif (396 bytes)